1 winpinup azmostbetpinup loginpin-up casinomostbet kzmostbet indiamosbet aviator4r bet1win loginlucyjetmosbetonewin1 win4r betmostbet casino1 win aviator1win kzparimatch1win yükləmostbetpin upmostbetonewin casinolucky jetmosbetmosbet casinopin up az1 вин авиаторlucky jet onlineparimatchmosbet india1 win casinopin up azpin up casinopin up kz4rabet bangladesh1win casino4rabet1win aposta1win aviator1win casinolucky jet1winpin-upмостбет кзmostbet casinoaviatorlucky jet crashpin up betmostbet casino
40 Great Gulf Dr unit 39, Vaughan, ON

1.3 Thermostat Setting

After the thermostat has been connected to the Kinghome PLUS app, complete the following settings on the Kinghome Thermostat (Model: WK-010WD).

Before setting the thermostat for the first time, set the thermostat mode to OFF.

User Setup

  1. Function > User Setup > Time, turn on “Synchronize Time with APP” .
  2. Function > User Setup > Max Heat Setpoint set to maximum 32 °C.

Installation Parameters

  1. Function > Installation Parameters > Indoor Unit Type set to Furnace (specifically, you need to check the type of furnace and select 1st FUR/2nd FUR).
  2. Function > Installation Parameters > DualFuel Switch Timer and set it to 10 minutes.
  3. Function > Installation Parameters > Temperature Display Revise recommended to set it to 0°C. This function perform a temperature deviation correction. Set it based on the difference between the current indoor ambient temperature and the default value displayed on the thermostat.
  4. Function > Installation Parameters > Compressor on Timer and set the time to 1 minute. This feature will protect the compressor.

Note: To determine the furnace type, refer to the furnace serial number that usually located on the inside of the furnace.